Roof 1 Is the PV array mechanically installed to comply with manufacturer’s installation instructions (for example, foot spacing, fixing type, end clamps, etc) and is in compliance with manufacturer’s engineering certification and AS/NZS 1170.2 and may present a hazard to person or property? Applicable rating: Needs rectification | AS/NZS 5033:2021 Clause 4.3.2.2.5 AS/NZS 1170.2:2021 |
Roof 20 Is the PV array securely installed to manufacturer’s installation instructions, (for example, fixing type, clamping zones, mid clamps, etc), and in compliance with manufacturers engineering certification and AS/NZS 1170.2 and does not present a hazard to person or property? Applicable rating: Improvements identified (For information) | AS/NZS 5033:2021 Clause 4.3.2.2.6. |
Roof 2 Are PV Module mounting frames, and the methods used for attaching PV Modules to frames and frames to buildings made from corrosion resistant materials? Applicable rating: Improvements identified (For information) | AS/NZS 5033:2021 Clause 4.3.2.2.8 |
Roof 3 Have all roof tiles been installed so they sit flat after the installation of tile mounting brackets to ensure the tiles maintain their original ingress protection? Note: There may be a requirement to grind the underside of the tile to enable it to sit correctly. Applicable rating: Needs rectification | SAA requirements V1.2 Clause 5.1.3 AS/NZS 5033:2021 clause 4.3.2.2.1 and 4.4.5.1 |
Roof 24 Where the PV array cable and conduit passes through a tile or steel roof, has a fit for purpose collar flashing been installed? (for example, dektite), and has it been installed to last the lifetime of the system? Applicable rating: Needs rectification | SAA requirements V1.2 Clause 5.3.1 AS/NZS 5033:2021 clause 4.3.2.2.1 and 4.4.5.1 |
Roof 25 Have all cables and cable enclosures (including any penetrations) been installed so they do not obstruct natural water drain paths or promote the accumulation of debris? Applicable rating: Needs rectification | AS/NZS 3000:2018 clause 3.10.3.1 AS/NZS 5033:2021 clauses 4.3.2.3.1 (f) and 4.4.5.1 (b) |
Roof 6 Do all PV DC Array cables conform to these requirements: - insulated and sheathed UV resistant cables have been used?
- cables have been protected from mechanical damage?
- cables have been clamped to prevent undue strain on connections/terminations?
- cables do not lie on roofs?
- cables do not obstruct the natural flow of water or promote accumulation of debris?
- plastic cable ties shall not be used as the primary method of support?
- cables shall be protected against abrasion, tension, compression and cutting forces that may arise from thermal cycles, wind and other forces?
- cables have been supported so they do not suffer fatigue due to wind/snow effects?
Applicable rating: Improvements identified (For information) | AS/NZS 5033:2021 Clause 4.3.2.3.1 |
Roof 7 Are all conduits exposed to sunlight adequately installed and protected from UV or UV rated? Applicable rating: Improvements identified (For information) | AS/NZS 5033:2021 Clause 4.4.4.1 |
Roof 8 Is the DC array wiring and wiring to inverter rated for the appropriate voltage and current? Applicable rating: Needs rectification | AS/NZS 5033:2021 Clause 4.4.2.1 |
Roof 9 Are all joints in cables enclosed in junction boxes comply with the exceptions of AS/NZS3000 Clause 3.7.3? Applicable rating: Improvements identified (For information) | AS/NZS 3000 Clause 3.7.3 and 3.7.2.8 |
Roof 21 Is all PV DC wiring located in a ceiling space between nonadjacent groups of PV modules, not installed within 0.6m above the ceiling surface if further than 1.5m from the internal surface of an external wall? Applicable rating: Needs rectification | AS/NZS 5033:2021 Clause 4.4.5.2.4 (a) |
Roof 22 Is all PV DC wiring located in a ceiling space between nonadjacent groups of PV modules, attached to the roof structure if installed between 1 and 1.5m of an external wall and less than 0.6m above the surface of the ceiling? Applicable rating: Needs rectification | AS/NZS 5033:2021 Clause 4.4.5.2.4 (b) |
Roof 15 Do all PV Array DC cables conform to these requirements: - conforms to IEC 62930 where not installed underground?
- suitable for DC applications?
- has a temperature rating appropriate for the application?
- if exposed to the environment, is IV-resistant, or is protected from UV light by appropriate protection?
- cables directly terminated to plugs, socket and connectors are class 5 (flexible) in accordance with IEC 60228?
Applicable rating: Needs rectification | AS/NZS 5033:2021 Clause 4.4.2.1 |
Roof 17 Where the calculated PV DC circuit maximum voltage is greater than 35V, have the following exposed conductive parts earthed with an impedance of less than 0.5 ohms: - all conductive PV module frames?
- array mounting frames that are directly in contact with the PV DC cables?
- conductive cable support systems or conductive wiring enclosures that are directly in contact with PV DC cables?
- if above 0.5-ohm impedance is recorded, has a voltage greater than 5Vac been measured between main earth and the conductive material using a low impendence meter?
Applicable rating: Unsafe | AS/NZS 5033:2021 Clause 4.6.2 and 4.6.5 AS/NZS 3000:2018 Clauses 5.6.2.1(e) and 7.3.6 |
Roof 17.1 Where the calculated PV DC circuit maximum voltage is greater than 35V, have the following exposed conductive parts earthed with an impedance of less than 0.5 ohms: - all conductive PV module frames?
- array mounting frames that are directly in contact with the PV DC cables?
- conductive cable support systems or conductive wiring enclosures that are directly in contact with PV DC cables?
Applicable rating: Needs rectification | AS/NZS 5033:2021 Clause 4.6.2 and 4.6.5 AS/NZS 3000:2018 Clauses 5.6.2.1(e) and 7.3.6 |
Roof 18 All earthing cables for the frame earth connections are of adequate size to comply with standards. Applicable rating: Improvements identified (For information) | AS/NZS 5033:2021 Clause 4.6.5 |
Roof 19 Do the PV array frame and module earthing connections and methods comply with Australian Standards (AS/NZS3000:2018 and AS/NZS5033:2014)? Applicable rating: Improvements identified (For information) | AS/NZS 5033:2021 Clause 4.6.3 AS/NZS 3000:2018 Clause 3.7.2.6 |